SUTRON Stage Discharge Recorder, with shaft encoder only and SD Card Slot
SUTRON Stage Discharge Recorder, with shaft encoder only and SD Card Slot
SDR-2
SDR-N2
SDR-N3
SDR-3
SDR-9

SUTRON Stage Discharge Recorder, with shaft encoder only and SD Card Slot

Product Number: SDR-0001-1SD
Shaft Encoder
SD Card
Analogue inputs
This product has been discontinued. Please connect with your sales representative for assistance.

Overview

SDR is a Logging Shaft Encoder used in surface water & groundwater applications. Front panel programmable, it holds over one year of data, & operates for over one year on alkaline batteries. SDR supports dual sensors to measure a second stage using an analog or SDI-12 sensor. It supports rating tables and incorporates standard flume and weir equations.

Benefits

Dual sensor

Setup SDR to measure a second stage using an analog* or SDI-12 sensor.

Rating table

Compute discharge using a rating table with up to 50 points.

Averaging

Stage can be computed by averaging multiple samples over a user-set period.

Specifications

-
Technical Attributes
Operating temp range 1 -40 - +140 °F (-40 - +60 °C)
Resolution Shaft encoder has 400 count / revolution
Control and Display Display Type: 2 x 20 LCD with backlight Keypad Type: 6 button
Mounting configurations Supported Wheels: 1 ft, 0.375, 0.5 m, and custom
SD Card Yes
Data storage ˃ 300,000 readings
Programming Via front panel or SDR communicator program
Analogue inputs No
Measuring interval 15-minute (default) 1, 5, and 10-min user selectable
Protocol MODBUS Slave. SCP, SDI-12
Calculations Discharge using Parshall Flume, Broad Crested Weir equations, Dual Sensor, Rating Table or general purpose equation with user entered constants. Calculation of daily volume and daily average stage.
Power Consumption ˂3.5 mA @12 VDC
Material enclosures NEMA 3, IP63 resists dripping water & spray
Power supply 5.5 - 16 VDC
Analog Output No
Shaft Encoder Yes
Dimensions (free text) 4.5 x 4 x 7 in (11.5 x 10.2 x 17.8 cm)
Parameters Measured Stage / Water Level, Internal Temperature, Battery
Shaft Length 5/16" Diameter
Interface SDI-12, RS-232