toggle menu

Groundwater

Measuring groundwater level or depth-to-water is critically important for identifying long term trends, including declining water levels, saltwater intrusion, seasonal variations, aquifer recharge, artificial aquifer storage and recovery, and level status for drinking water. Receiving groundwater data via remote data transmission from one of the many OTT telemetry options available saves time and resources spent in the field.

Certain Hydrolab multiparameter instrumentation is also compact enough to fit in groundwater to measure groundwater quality in detail. Hydrolab sensors can also be equipped with a Rhodamine sensor to be used in in dye tracing studies to track water flow direction.

Groundwater level sensor and data logger

OTT ecoLog 500 Water Level Logger

Water level sensor with built-in datalogger for surface and groundwater applications

The OTT ecoLOG 500 is a self-contained water level instrument offering flexible remote data options and unequaled performance for the price.

  • Surface water Groundwater
  • Vented pressure cell
  • Waterlevel/Pressure, Water temperature
  • Measures, stores, and transmits water level and temperature data
  • ± 0.05% FS
  • Yes
Longterm monitoring of conductivity, temperature and water level

OTT ecoLog 800 Water Level Logger

Groundwater level and conductivity sensor with built-in datalogger and telemetry

The OTT ecoLog 800 is a self-contained system for measurement of water level, temperature, and conductivity in groundwater and surface water applications.

  • Surface water Groundwater
  • Vented pressure cell and 4-electrode graphite conductivity cell
  • Waterlevel/Pressure, Water temperature, Conductivity
  • Measures, stores, and transmits water level and temperature data
  • 0 … 4, 10, 20, 40, and 100 m
  • ± 0.05% FS
  • Yes
Integrated pressure level transducer and datalogger

OTT Orpheus Mini Water Level Logger

Pressure level transducer with datalogger for longterm groundwater monitoring

The OTT Orpheus Mini is an integrated pressure sensor and datalogger for level measurement in surface and groundwater applications.

  • Surface water Groundwater
  • Vented pressure cell
  • Waterlevel/Pressure, Water temperature
  • Measures and stores water level and temperature data
  • 0 … 4, 10, 20, 40, and 100 m
  • ± 0.05% FS
  • Yes
With integrated sensor and datalogger for longterm monitoring

OTT CTD Sensor

Pressure sensor for longterm measurement of conductivity, temperature and water level

The OTT CTD is an integrated sensor and datalogger for measurement of water level, temperature, and conductivity in groundwater and surface water applications.

  • Surface water Groundwater
  • Vented pressure cell and 4-electrode graphite conductivity cell
  • Waterlevel, Temperature, Conductivity
  • Measures and stores water level, temperature, and conductivity data
  • Water level: 0 … 4, 10, 20, 40, and 100 m Conductivity: 0.001…2.000 mS/cm, 0.10…100.00 mS/cm
  • ±0,05 % FS
  • Yes
OTT PLS - vented pressure transducer

OTT PLS - Pressure Level Sensor

Robust ceramic pressure transducer for water level measurement

The OTT PLS, SDI-12 or 4 ... 20 mA pressure probe, measures water level, depth to water, or pressure using an integrated controller and ceramic pressure-measuring cell.

  • Surface water Groundwater
  • Vented pressure cell
  • Water level, Pressure, Temperature
  • Water level and temperature measurement - for use with external data logger
  • 0 … 4, 10, 20, 40, and 100 m
  • ± 0.05% FS
  • No
  • SDI-12, RS-485 (using SDI-12), or 4 … 20 mA
pressure probe with conductivity measurement cell OTT PLS-C

OTT PLS-C

Pressure probe with conductivity measurement cell

The OTT PLS-C measures water conductivity, level, and temperature in both surface and groundwater applications via a robust ceramic pressure cell and 4-electrode conductivity cell.

  • Surface water Groundwater
  • Vented pressure cell and 4-electrode graphite conductivity cell
  • Water level, Pressure, Conductivity, Temperature
  • Water level, temperature, and conductivity measurement - for use with external data logger
  • No
  • SDI-12 or RS-485 (using SDI-12)
Contact gauge OTT KL010

OTT Contact Gauges

OTT Contact Gauges for measurements of depth to water, temperature and conductivity

OTT Contact Gauges are essential for manual water level measurements in groundwater. For measuring depth to water, temperature, and conductivity – depending on the variant.

  • Measuring tape lengths KL010: 15 ... 750 m; KL010 TM: 25 ... 500 m; KL010 TCM 30 ... 500 m
  • Groundwater
  • Contact gauge
  • Water level / Distance to water, Temperature, Conductivity
  • Manual water level, temperature and/or conductivity measurement
New water quality sonde platform: ease of use, meta-data, reliability

Hydrolab HL4 Multiparameter Sonde

New Hydrolab Platform: Reliability, Ease-of-use, Metadata

The Hydrolab HL4 is the next generation multiparameter water quality sonde from OTT Hydromet. Its reliability, ease-of-use, and metadata produce water quality data you can trust.

  • Attended Unattended
  • Temperature, Conductivity, Depth, pH, Dissolved Oxygen (LDO), Turbidity, ORP
  • The next generation multiparameter water quality instrument
  • SDI-12, RS-485, RS-232, TTY, USB
Lightweight multi-probe water quality testing instrument

Hydrolab MS5 - Mulitparameter Mini Sonde

Lightweight multi-probe with four ports available for water quality sensors

The Hydrolab MS5 multiparameter water quality sonde offers a selection of Hydrolab sensors on a compact and lightweight multiprobe designed for either profiling or unattended monitoring.

  • Attended Unattended
  • Temperature, Conductivity, Depth, pH ,ORP, Dissolved Oxygen (LDO, Clark cell), Turbidity, Chlorophyll a, Blue-Green Algae, Rhodamine WT, Ammonium, Nitrate, Chloride , TDG
  • The Hydrolab sonde profile for a smaller sensor payload that will fit in a two-inch well
  • SDI-12, RS-485, RS-232, TTY
Basic water quality measurements in groundwater

Hydrolab Quanta G Multi-Probe Meter

Basic water quality sensors for spot measurements in groundwater wells

For basic water quality parameter spot measurements in groundwater wells, the Quanta-G offers Hydrolas sensor technology in a complete stainless steel package that includes an easy-to-use, handheld display.

  • Attended
  • Temperature, Conductivity, Depth, pH, Oxygen Reduction Potential (ORP), Dissolved Oxygen (Clark Cell)
  • The Hydrolab sonde for basic spot measurements that will fit in a two-inch well
  • SDI-12
OTT ecoLog 500 Video - EN
OTT ecoLog 500 Video
OTT Groundwater Sensor Selection Guide
Back to overview