Lufft Ventus-UMB Ultrasonic Wind Sensor
Product Number: 8371.UMTVENTUS is a robust, maintenance‑free high‑precision wind sensor delivering accurate wind speed, gust, and direction measurements during extreme weather conditions.
Wind Speed
Transducer Heater
Analog Output
Overview
VENTUS: Very robust, precise and maintenance-free measurement of wind speed, wind gust and wind direction even in the lowest temperature. The accurate wind sensor uses the run-time differential method for determining the wind speed and wind direction. It provides output for instantaneous values, vector and scalar means, the maximum gust of wind and wind direction, the maximum/minimum values and the virtual temperature. Data output through serial or analogue interfaces provides compatibility of the Lufft Ventus for commercially available hydrometeorological dataloggers and PLC systems. An automatic heater ensures reliable operation even in the lowest temperature.
Benefits
Vibration and seawater resistant, integrated heater guarantees ice-free operation in extremely low temperatures until -40 °C
Built-in data pre-processing, universal interfaces and selectable output protocols – compatible with OTT-dataloggers, commercially available HydroMet dataloggers and PLS systems.
Maintenance-free operation – no moving parts that can wear out thanks to ultrasonic measuring method; no need for re-calibration.
Specifications
Technical Attributes
| Sample rate | Instantaneous: 1 - 10 s Average: 1 - 10 min |
| Baud rate | 1200 - 57600 |
| Weight EU | Approx. 1.6 kg (3.6 lbs) |
| Factory Certificate | Yes |
| Analogue Outputs | 4 - 20 mA or 0 - 10 V |
| Resolution EU | Data output: 16 bit Wind Direction: 0.1 ° Wind Speed: 0.33 ft/s Virtual Temperature: 0.2 °F Air Pressure: 0.1 hPa |
| Transducer Heater | No |
| Product highlights | Ice-free operation in extreme freezing conditions due to additional transducer heater Maintenance-free measurement Suitable for extreme ambient conditions Vibration and seawater resistant Compatible interfaces |
| Analogue Ouput Signal | 4 - 20 mA or 0 - 10 V or 2 - 2000 Hz |
| Testing | Jarring Test: According to IEC 60945 Corrosion Test: According to MIL-STD-810 Method 509.3 Ice-free Test: According to MIL-STD-810F Method 521.2 Highly Accelerated Life Test |
| Analog Output | Yes |
| Operating voltage | 12 - 24 VDC / 1.2 VA (without heating) 24 VDC / 240 VA (140 VA + 100 VA) (with heating) |
| Dimensions (free text) | Ø approx. 5.9 in (150 mm), H approx. 6.7 in (170 mm) |
| System Monitoring & Controls: Local Status Indication | Heating, sensor failure |
| Operating Height | 3827 yd (Max) (3500 m) |
| Ambient Temperature | -40 - +80 °C (-40 - +176 °F) |
| Diameter, Outer | Ø50 mm (2 in) |
| Accuracy | Wind Direction: ±2° RMSE |
| Measurement technology | Ultrasonic |
| Casing IP Rating | IP68 |
| Measurement Range EU | Wind Direction: 0 - 359.9 ° Wind Speed: 0 - 295.3 ft/s (0 - 90 m/s) Virtual Temperature: -58 - +158 °F (-50 - +70 °C) Air Pressure: 300 - 1200 hPa |
| Interface | RS485 semi-/full duplex, isolated |
| Cable Connection | 8 pole plug |
| Housing material | Aluminium, seawater - proof |
| Wind Speed | 0 - 90 m/s (0 - 295 ft/s) |
| Bus Operation | Up to 32 devices |