Germany
HomeAboutProductsSystemsProjectsSupportmyOTT
Water level
Discharge
Continuous measurements
Spot measurements
C31 Universal Current Meter
C2 Small Current Meter
ADC
MF pro
Qliner 2
Signal Counter Z400
Meteorology
Water Quality
Data Loggers
Operating / Reading Unit
Software solution
Communication
System solutions

Produktlinks

 
 
 
Printversion

Signal Counter OTT Z400

Technical Data



Power Supply9 V... 4 V
Reverse Voltage Protection
yes
'Low Battery' Display
yes (<5,35 V)

Current draw
'PowerDown':


22 µA
Current draw
'Standby' (Stop):

4,5 mA
Current draw measurement (Start):
4,5 mA
Measurement method
Starts measuring time when current meter contact closes for the first time
Measurment times
5, 10, 15, 20, 30, 40, 50, 60, 80, 100,120 s and unending
Measurment modes
Impulse-, time-, integration- and integration measurement with remaining term determination
Resolution:
time measurement
impulse measurement


0.1 s
0.1 impulse

Accuracy:
time measurement
impulse measurement


+/- 0.01 s
+/- 0.5 impulse

„Timeout time“ for unending measurement time
no
Limit frequency for current meter impulses50 Hz (680 Ohm) / 100 Hz
Measurement with 680 Ohm (series) possible
yes
Display of flow velocityoptional
Automatic switching off
yes (can be set freom 1... 59 minutes)
Display for impulses
LCD, 4-digit, numbers 10 mm
Counting methodadditive
Counting range9999, no overflow

General Data

Cable connection2 banana plugs
Ø 4 mm, red '+' / black 'F'
Power supply
9 V battery ( IEC6LR61)
battery life:
120 hours without buzzer
80 hours with buzzer
Power controlBattery symbol displayed
symbol appears - remaining battery life sufficient for approx. 8 h of operation at room temperature
Material of housingaluminium
Ambient temperature allowed
- 20 °C ... + 60 °C
Dimensions with rubber covers128 mm x 125 mm x 65 mm (l x w x h)
Dimensions without rubber covers
121 mm x 125 mm x 49 mm (l x w x h)
Weight, complete
670 g
ProtectionIP65
Interface:USB 1.1
4 MB Storage

PC - Operating software - directly via USB
Input of 30  current meter equations (optional)
Setting of all instrument parameters possible

 




germanenglish HomeNewsSitemapContactSearchImprint & Privacy Policy
voilà cms 3.1 tracker
VOILA_REP_ID=C1257020:002D2AC0